Skip to content

ISO 286 · f7 shaft · Ø50 mm

50 mm f7 Tolerance — Shaft Limits in mm and µm

A 50 mm f7 shaft is 49.950 to 49.975 mm — deviations of -50 to -25 µm on an IT7 band 25 µm wide. Close running shaft — the standard choice for lubricated journals at moderate speed. Values apply at the ISO 286 reference temperature of 20 °C.

Nominal
50 mm
Designation
f7
Feature
shaft
Grade
IT7
Band
25 µm

50 mm f7 shaft · limits, mm

49.950 … 49.975

Upper dev
-25µm
Lower dev
-50µm
Band
25µm

Measured at 20 °C on a plain cylindrical feature. The IT7 grade sets the 25 µm width; the f sets where the band sits.

Limits for a 50 mm f7 Shaft

Deviations in micrometres, finished limits in millimetres. Both describe the same band — the deviation is what a drawing carries, the limit is what a gauge reads.

50 mm f7 shaft tolerance — deviations and limits
Limitµmmm
Upper deviation-25-0.025
Lower deviation-50-0.050
Maximum diameter-2549.975
Minimum diameter-5049.950
Tolerance band (IT7)250.025

Deviations are relative to the 50 mm nominal size. Values apply at the ISO 286 reference temperature of 20 °C; a part measured warm is not at these limits.

ISO 286 Tolerance Grades at 50 mm

50 mm falls in the ISO 286 size band over 30 to 50 mm, so every tolerance in that band has the same width regardless of which letter it carries.

ISO 286 standard tolerance grades at 50 mm nominal size
GradeTolerance, µmTolerance, mm
IT5110.011
IT6160.016
IT7250.025
IT8390.039
IT9620.062
IT101000.100
IT111600.160
IT122500.250

The grade sets the width of the band; the letter sets where that band sits relative to the nominal size.

Every Other ISO 286 Tolerance at 50 mm

The same nominal size under every other designation in this reference — the comparison that decides whether a feature is called out f7 or something looser.

ISO 286 hole and shaft tolerances at 50 mm nominal size
PropertyPropertyDeviation, µmLimits, mm
DesignationApplies toUpperLowerMinMax
c11shaft-130-29049.71049.870
d9shaft-80-14249.85849.920
e8shaft-50-8949.91149.950
f7shaft-25-5049.95049.975
g6shaft-9-2549.97549.991
h11shaft0-16049.84050.000
h6shaft0-1649.98450.000
h7shaft0-2549.97550.000
h9shaft0-6249.93850.000
k6shaft+18+250.00250.018
m6shaft+25+950.00950.025
n6shaft+33+1750.01750.033
p6shaft+42+2650.02650.042
r6shaft+50+3450.03450.050
F8hole+64+2550.02550.064
G7hole+34+950.00950.034
H11hole+160050.00050.160
H6hole+16050.00050.016
H7hole+25050.00050.025
H8hole+39050.00050.039
H9hole+62050.00050.062
K7hole+7-1849.98250.007
N7hole-8-3349.96749.992
P7hole-17-4249.95849.983

Links go to that designation's page for this size where one exists, and to its full size table otherwise.

Standard Fits Available at 50 mm

What each standard hole/shaft pair gives at 50 mm, loosest first. Negative clearance is interference.

ISO 286 fits and their clearance at 50 mm nominal size
PropertyPropertyClearance, µmProperty
FitTypeMinMaxWhat it is for
H7/h6clearance0+41Locational clearance. Assembles by hand, no free movement intended.
H11/c11clearance+130+450Loose running. Wide commercial tolerances, large clearance for dirt, paint and thermal growth.
H9/d9clearance+80+204Free running. Good where accuracy is not essential and clearance can be generous.
H8/e8clearance+50+128Running fit with room for a lubricant film at speed.
H8/f7clearance+25+89Close running. The general-purpose lubricated journal fit.
H7/g6clearance+9+50Sliding. Locates accurately, still moves and turns freely.
H7/k6transition-18+23Locational transition. Accurate location, assembles with light force.
H7/m6transition-25+16Locational transition, tighter than k6.
H7/n6transition-33+8Tight transition. Usually a press job.
H7/p6interference-42-1Locational interference. Rigid location in steel without the load capacity of a drive fit.
H7/r6interference-50-9Medium drive. The joint itself carries load.
F8/h7clearance+25+89Close running, shaft basis.
G7/h6clearance+9+50Sliding, shaft basis. The h6 shaft is the reference and the hole carries the clearance.
K7/h6transition-18+23Locational transition, shaft basis.
N7/h6transition-33+8Tight transition, shaft basis.
P7/h6interference-42-1Locational interference, shaft basis.

Minimum clearance is the largest shaft in the smallest hole; maximum clearance is the smallest shaft in the largest hole.

Sources and Method for the 50 mm f7 Tolerance

50 mm f7 limitscomputed

limits computed from the compiled ISO 286 tables: ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed

Computed from the standard's formulas, then checked against published tables.

IT tolerance gradescompiled

ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed. Formula per ISO 286-1 standard tolerance factor and fundamental deviation formulas, used as a validation harness only per docs/research/data-sourcing.md §3.6

Compiled from independent public sources that agree cell-for-cell.

Formula

Limits from the deviations at 50 mm

max Ø  =  50 mm + (-25 µm)  =  49.975 mm
min Ø  =  50 mm + (-50 µm)  =  49.950 mm

The deviations are compiled from the ISO 286-2 tables; the limits are those deviations applied to the nominal size.

Assumptions
  • Values apply at the ISO 286 reference temperature of 20 °C.
  • Size only. Form, roundness, cylindricity and surface finish are separate callouts and a part inside these limits can still be unusable without them.
  • Dataset scope: COMPILED not computed: the ISO 286-1 formula deviates up to 13.26% from the table and is used only as a harness (warn >5%, fail >15%). EXCLUDED: shaft/hole letters s, t, u and the fits H7/s6, H7/t6, H7/u6 — no free source and an undetermined step constant in the formula.
Data last verified
August 1, 2026
How this data is built and checked →

How to Cite This 50 mm f7 Tolerance Reference

Citation

ShopMath. "50 mm f7 Tolerance — Shaft Limits in mm and µm." ShopMath, verified August 1, 2026, https://shopmath.org/fits/f7/50mm

BibTeX

@misc{shopmath-fits-f7-50mm,
  title        = {50 mm f7 Tolerance — Shaft Limits in mm and µm},
  author       = {{ShopMath}},
  year         = {2026},
  howpublished = {\url{https://shopmath.org/fits/f7/50mm}},
  note         = {Data verified 2026-08-01}
}

Permanent URL

https://shopmath.org/fits/f7/50mm

Common Questions About the 50 mm f7 Tolerance

What is the tolerance for a 50 mm f7 shaft?

A 50 mm f7 shaft runs 49.950 to 49.975 mm — deviations of -50 to -25 µm, a band 25 µm wide.

What is the maximum and minimum size of a 50 mm f7 shaft?

Maximum 49.975 mm, minimum 49.950 mm. Anything outside that band is a reject at 20 °C, not a judgement call.

Why is the IT7 band 25 µm at 50 mm?

Because 50 mm falls in the ISO 286 size band over 30 up to 50 mm, and IT7 is defined per band rather than per size. Every nominal size in that band carries the same 25 µm width for IT7.

What shaft goes in a 50 mm f7 hole?

At 50 mm the standard pairs run from H7/h6 (0 to +41 µm clearance) through transition to interference fits — the full list with clearances is on this page.

What does the f in f7 mean?

Close running clearance. It fixes the fundamental deviation — the limit nearest the nominal size — while IT7 fixes the width of the band, which at 50 mm is 25 µm.

All 13 f7 sizes · ISO 286 tolerance chart · Every designation and fit