Skip to content

ISO 286 · h6 shaft · Ø6 mm

6 mm h6 Tolerance — Shaft Limits in mm and µm

A 6 mm h6 shaft is 5.992 to 6.000 mm — deviations of -8 to 0 µm on an IT6 band 8 µm wide. Precision basic shaft — zero upper deviation, the reference for locational clearance fits. Values apply at the ISO 286 reference temperature of 20 °C.

Nominal
6 mm
Designation
h6
Feature
shaft
Grade
IT6
Band
8 µm

6 mm h6 shaft · limits, mm

5.992 … 6.000

Upper dev
0µm
Lower dev
-8µm
Band
8µm

Measured at 20 °C on a plain cylindrical feature. The IT6 grade sets the 8 µm width; the h sets where the band sits.

Limits for a 6 mm h6 Shaft

Deviations in micrometres, finished limits in millimetres. Both describe the same band — the deviation is what a drawing carries, the limit is what a gauge reads.

6 mm h6 shaft tolerance — deviations and limits
Limitµmmm
Upper deviation00.000
Lower deviation-8-0.008
Maximum diameter06.000
Minimum diameter-85.992
Tolerance band (IT6)80.008

Deviations are relative to the 6 mm nominal size. Values apply at the ISO 286 reference temperature of 20 °C; a part measured warm is not at these limits.

ISO 286 Tolerance Grades at 6 mm

6 mm falls in the ISO 286 size band over 3 to 6 mm, so every tolerance in that band has the same width regardless of which letter it carries.

ISO 286 standard tolerance grades at 6 mm nominal size
GradeTolerance, µmTolerance, mm
IT550.005
IT680.008
IT7120.012
IT8180.018
IT9300.030
IT10480.048
IT11750.075
IT121200.120

The grade sets the width of the band; the letter sets where that band sits relative to the nominal size.

Every Other ISO 286 Tolerance at 6 mm

The same nominal size under every other designation in this reference — the comparison that decides whether a feature is called out h6 or something looser.

ISO 286 hole and shaft tolerances at 6 mm nominal size
PropertyPropertyDeviation, µmLimits, mm
DesignationApplies toUpperLowerMinMax
c11shaft-70-1455.8555.930
d9shaft-30-605.9405.970
e8shaft-20-385.9625.980
f7shaft-10-225.9785.990
g6shaft-4-125.9885.996
h11shaft0-755.9256.000
h6shaft0-85.9926.000
h7shaft0-125.9886.000
h9shaft0-305.9706.000
k6shaft+9+16.0016.009
m6shaft+12+46.0046.012
n6shaft+16+86.0086.016
p6shaft+20+126.0126.020
r6shaft+23+156.0156.023
F8hole+28+106.0106.028
G7hole+16+46.0046.016
H11hole+7506.0006.075
H6hole+806.0006.008
H7hole+1206.0006.012
H8hole+1806.0006.018
H9hole+3006.0006.030
K7hole+3-95.9916.003
N7hole-4-165.9845.996
P7hole-8-205.9805.992

Links go to that designation's page for this size where one exists, and to its full size table otherwise.

Standard Fits Available at 6 mm

What each standard hole/shaft pair gives at 6 mm, loosest first. Negative clearance is interference.

ISO 286 fits and their clearance at 6 mm nominal size
PropertyPropertyClearance, µmProperty
FitTypeMinMaxWhat it is for
H7/h6clearance0+20Locational clearance. Assembles by hand, no free movement intended.
H11/c11clearance+70+220Loose running. Wide commercial tolerances, large clearance for dirt, paint and thermal growth.
H9/d9clearance+30+90Free running. Good where accuracy is not essential and clearance can be generous.
H8/e8clearance+20+56Running fit with room for a lubricant film at speed.
H8/f7clearance+10+40Close running. The general-purpose lubricated journal fit.
H7/g6clearance+4+24Sliding. Locates accurately, still moves and turns freely.
H7/k6transition-9+11Locational transition. Accurate location, assembles with light force.
H7/m6transition-12+8Locational transition, tighter than k6.
H7/n6transition-16+4Tight transition. Usually a press job.
H7/p6interference-200Locational interference. Rigid location in steel without the load capacity of a drive fit.
H7/r6interference-23-3Medium drive. The joint itself carries load.
F8/h7clearance+10+40Close running, shaft basis.
G7/h6clearance+4+24Sliding, shaft basis. The h6 shaft is the reference and the hole carries the clearance.
K7/h6transition-9+11Locational transition, shaft basis.
N7/h6transition-16+4Tight transition, shaft basis.
P7/h6interference-200Locational interference, shaft basis.

Minimum clearance is the largest shaft in the smallest hole; maximum clearance is the smallest shaft in the largest hole.

Sources and Method for the 6 mm h6 Tolerance

6 mm h6 limitscomputed

limits computed from the compiled ISO 286 tables: ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed

Computed from the standard's formulas, then checked against published tables.

IT tolerance gradescompiled

ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed. Formula per ISO 286-1 standard tolerance factor and fundamental deviation formulas, used as a validation harness only per docs/research/data-sourcing.md §3.6

Compiled from independent public sources that agree cell-for-cell.

Formula

Limits from the deviations at 6 mm

max Ø  =  6 mm + (0 µm)  =  6.000 mm
min Ø  =  6 mm + (-8 µm)  =  5.992 mm

The deviations are compiled from the ISO 286-2 tables; the limits are those deviations applied to the nominal size.

Assumptions
  • Values apply at the ISO 286 reference temperature of 20 °C.
  • Size only. Form, roundness, cylindricity and surface finish are separate callouts and a part inside these limits can still be unusable without them.
  • Dataset scope: COMPILED not computed: the ISO 286-1 formula deviates up to 13.26% from the table and is used only as a harness (warn >5%, fail >15%). EXCLUDED: shaft/hole letters s, t, u and the fits H7/s6, H7/t6, H7/u6 — no free source and an undetermined step constant in the formula.
Data last verified
August 1, 2026
How this data is built and checked →

How to Cite This 6 mm h6 Tolerance Reference

Citation

ShopMath. "6 mm h6 Tolerance — Shaft Limits in mm and µm." ShopMath, verified August 1, 2026, https://shopmath.org/fits/h6/6mm

BibTeX

@misc{shopmath-fits-h6-6mm,
  title        = {6 mm h6 Tolerance — Shaft Limits in mm and µm},
  author       = {{ShopMath}},
  year         = {2026},
  howpublished = {\url{https://shopmath.org/fits/h6/6mm}},
  note         = {Data verified 2026-08-01}
}

Permanent URL

https://shopmath.org/fits/h6/6mm

Common Questions About the 6 mm h6 Tolerance

What is the tolerance for a 6 mm h6 shaft?

A 6 mm h6 shaft runs 5.992 to 6.000 mm — deviations of -8 to 0 µm, a band 8 µm wide.

What is the maximum and minimum size of a 6 mm h6 shaft?

Maximum 6.000 mm, minimum 5.992 mm. Anything outside that band is a reject at 20 °C, not a judgement call.

Why is the IT6 band 8 µm at 6 mm?

Because 6 mm falls in the ISO 286 size band over 3 up to 6 mm, and IT6 is defined per band rather than per size. Every nominal size in that band carries the same 8 µm width for IT6.

What shaft goes in a 6 mm h6 hole?

At 6 mm the standard pairs run from H7/h6 (0 to +20 µm clearance) through transition to interference fits — the full list with clearances is on this page.

What does the h in h6 mean?

Zero deviation — the basic shaft. It fixes the fundamental deviation — the limit nearest the nominal size — while IT6 fixes the width of the band, which at 6 mm is 8 µm.

All 13 h6 sizes · ISO 286 tolerance chart · Every designation and fit