Skip to content

ISO 286 · h7 shaft · Ø5 mm

5 mm h7 Tolerance — Shaft Limits in mm and µm

A 5 mm h7 shaft is 4.988 to 5.000 mm — deviations of -12 to 0 µm on an IT7 band 12 µm wide. Basic shaft one grade coarser than h6, for shaft-basis close running fits. Values apply at the ISO 286 reference temperature of 20 °C.

Nominal
5 mm
Designation
h7
Feature
shaft
Grade
IT7
Band
12 µm

5 mm h7 shaft · limits, mm

4.988 … 5.000

Upper dev
0µm
Lower dev
-12µm
Band
12µm

Measured at 20 °C on a plain cylindrical feature. The IT7 grade sets the 12 µm width; the h sets where the band sits.

Limits for a 5 mm h7 Shaft

Deviations in micrometres, finished limits in millimetres. Both describe the same band — the deviation is what a drawing carries, the limit is what a gauge reads.

5 mm h7 shaft tolerance — deviations and limits
Limitµmmm
Upper deviation00.000
Lower deviation-12-0.012
Maximum diameter05.000
Minimum diameter-124.988
Tolerance band (IT7)120.012

Deviations are relative to the 5 mm nominal size. Values apply at the ISO 286 reference temperature of 20 °C; a part measured warm is not at these limits.

ISO 286 Tolerance Grades at 5 mm

5 mm falls in the ISO 286 size band over 3 to 6 mm, so every tolerance in that band has the same width regardless of which letter it carries.

ISO 286 standard tolerance grades at 5 mm nominal size
GradeTolerance, µmTolerance, mm
IT550.005
IT680.008
IT7120.012
IT8180.018
IT9300.030
IT10480.048
IT11750.075
IT121200.120

The grade sets the width of the band; the letter sets where that band sits relative to the nominal size.

Every Other ISO 286 Tolerance at 5 mm

The same nominal size under every other designation in this reference — the comparison that decides whether a feature is called out h7 or something looser.

ISO 286 hole and shaft tolerances at 5 mm nominal size
PropertyPropertyDeviation, µmLimits, mm
DesignationApplies toUpperLowerMinMax
c11shaft-70-1454.8554.930
d9shaft-30-604.9404.970
e8shaft-20-384.9624.980
f7shaft-10-224.9784.990
g6shaft-4-124.9884.996
h11shaft0-754.9255.000
h6shaft0-84.9925.000
h7shaft0-124.9885.000
h9shaft0-304.9705.000
k6shaft+9+15.0015.009
m6shaft+12+45.0045.012
n6shaft+16+85.0085.016
p6shaft+20+125.0125.020
r6shaft+23+155.0155.023
F8hole+28+105.0105.028
G7hole+16+45.0045.016
H11hole+7505.0005.075
H6hole+805.0005.008
H7hole+1205.0005.012
H8hole+1805.0005.018
H9hole+3005.0005.030
K7hole+3-94.9915.003
N7hole-4-164.9844.996
P7hole-8-204.9804.992

Links go to that designation's page for this size where one exists, and to its full size table otherwise.

Standard Fits Available at 5 mm

What each standard hole/shaft pair gives at 5 mm, loosest first. Negative clearance is interference.

ISO 286 fits and their clearance at 5 mm nominal size
PropertyPropertyClearance, µmProperty
FitTypeMinMaxWhat it is for
H7/h6clearance0+20Locational clearance. Assembles by hand, no free movement intended.
H11/c11clearance+70+220Loose running. Wide commercial tolerances, large clearance for dirt, paint and thermal growth.
H9/d9clearance+30+90Free running. Good where accuracy is not essential and clearance can be generous.
H8/e8clearance+20+56Running fit with room for a lubricant film at speed.
H8/f7clearance+10+40Close running. The general-purpose lubricated journal fit.
H7/g6clearance+4+24Sliding. Locates accurately, still moves and turns freely.
H7/k6transition-9+11Locational transition. Accurate location, assembles with light force.
H7/m6transition-12+8Locational transition, tighter than k6.
H7/n6transition-16+4Tight transition. Usually a press job.
H7/p6interference-200Locational interference. Rigid location in steel without the load capacity of a drive fit.
H7/r6interference-23-3Medium drive. The joint itself carries load.
F8/h7clearance+10+40Close running, shaft basis.
G7/h6clearance+4+24Sliding, shaft basis. The h6 shaft is the reference and the hole carries the clearance.
K7/h6transition-9+11Locational transition, shaft basis.
N7/h6transition-16+4Tight transition, shaft basis.
P7/h6interference-200Locational interference, shaft basis.

Minimum clearance is the largest shaft in the smallest hole; maximum clearance is the smallest shaft in the largest hole.

Sources and Method for the 5 mm h7 Tolerance

5 mm h7 limitscomputed

limits computed from the compiled ISO 286 tables: ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed

Computed from the standard's formulas, then checked against published tables.

IT tolerance gradescompiled

ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed. Formula per ISO 286-1 standard tolerance factor and fundamental deviation formulas, used as a validation harness only per docs/research/data-sourcing.md §3.6

Compiled from independent public sources that agree cell-for-cell.

Formula

Limits from the deviations at 5 mm

max Ø  =  5 mm + (0 µm)  =  5.000 mm
min Ø  =  5 mm + (-12 µm)  =  4.988 mm

The deviations are compiled from the ISO 286-2 tables; the limits are those deviations applied to the nominal size.

Assumptions
  • Values apply at the ISO 286 reference temperature of 20 °C.
  • Size only. Form, roundness, cylindricity and surface finish are separate callouts and a part inside these limits can still be unusable without them.
  • Dataset scope: COMPILED not computed: the ISO 286-1 formula deviates up to 13.26% from the table and is used only as a harness (warn >5%, fail >15%). EXCLUDED: shaft/hole letters s, t, u and the fits H7/s6, H7/t6, H7/u6 — no free source and an undetermined step constant in the formula.
Data last verified
August 1, 2026
How this data is built and checked →

How to Cite This 5 mm h7 Tolerance Reference

Citation

ShopMath. "5 mm h7 Tolerance — Shaft Limits in mm and µm." ShopMath, verified August 1, 2026, https://shopmath.org/fits/h7-shaft/5mm

BibTeX

@misc{shopmath-fits-h7-shaft-5mm,
  title        = {5 mm h7 Tolerance — Shaft Limits in mm and µm},
  author       = {{ShopMath}},
  year         = {2026},
  howpublished = {\url{https://shopmath.org/fits/h7-shaft/5mm}},
  note         = {Data verified 2026-08-01}
}

Permanent URL

https://shopmath.org/fits/h7-shaft/5mm

Common Questions About the 5 mm h7 Tolerance

What is the tolerance for a 5 mm h7 shaft?

A 5 mm h7 shaft runs 4.988 to 5.000 mm — deviations of -12 to 0 µm, a band 12 µm wide.

What is the maximum and minimum size of a 5 mm h7 shaft?

Maximum 5.000 mm, minimum 4.988 mm. Anything outside that band is a reject at 20 °C, not a judgement call.

Why is the IT7 band 12 µm at 5 mm?

Because 5 mm falls in the ISO 286 size band over 3 up to 6 mm, and IT7 is defined per band rather than per size. Every nominal size in that band carries the same 12 µm width for IT7.

What shaft goes in a 5 mm h7 hole?

At 5 mm the standard pairs run from H7/h6 (0 to +20 µm clearance) through transition to interference fits — the full list with clearances is on this page.

What does the h in h7 mean?

Zero deviation — the basic shaft. It fixes the fundamental deviation — the limit nearest the nominal size — while IT7 fixes the width of the band, which at 5 mm is 12 µm.

All 13 h7 sizes · ISO 286 tolerance chart · Every designation and fit