A 16 mm p6 shaft is 16.018 to 16.029 mm — deviations of +18 to +29 µm on an IT6 band 11 µm wide. Light interference shaft for locational press fits in steel. Values apply at the ISO 286 reference temperature of 20 °C.

Nominal
16 mm
Designation
p6
Feature
shaft
Grade
IT6
Band
11 µm

16 mm p6 shaft · limits, mm

16.018 … 16.029

Upper dev
+29µm
Lower dev
+18µm
Band
11µm

Measured at 20 °C on a plain cylindrical feature. The IT6 grade sets the 11 µm width; the p sets where the band sits.

Limits for a 16 mm p6 Shaft

Deviations in micrometres, finished limits in millimetres. Both describe the same band — the deviation is what a drawing carries, the limit is what a gauge reads.

16 mm p6 shaft tolerance — deviations and limits
Limitµmmm
Upper deviation+290.029
Lower deviation+180.018
Maximum diameter+2916.029
Minimum diameter+1816.018
Tolerance band (IT6)110.011

Deviations are relative to the 16 mm nominal size. Values apply at the ISO 286 reference temperature of 20 °C; a part measured warm is not at these limits.

ISO 286 Tolerance Grades at 16 mm

16 mm falls in the ISO 286 size band over 10 to 18 mm, so every tolerance in that band has the same width regardless of which letter it carries.

ISO 286 standard tolerance grades at 16 mm nominal size
GradeTolerance, µmTolerance, mm
IT580.008
IT6110.011
IT7180.018
IT8270.027
IT9430.043
IT10700.070
IT111100.110
IT121800.180

The grade sets the width of the band; the letter sets where that band sits relative to the nominal size.

Every Other ISO 286 Tolerance at 16 mm

The same nominal size under every other designation in this reference — the comparison that decides whether a feature is called out p6 or something looser.

ISO 286 hole and shaft tolerances at 16 mm nominal size
PropertyPropertyDeviation, µmLimits, mm
DesignationApplies toUpperLowerMinMax
c11shaft-95-20515.79515.905
d9shaft-50-9315.90715.950
e8shaft-32-5915.94115.968
f7shaft-16-3415.96615.984
g6shaft-6-1715.98315.994
h11shaft0-11015.89016.000
h6shaft0-1115.98916.000
h7shaft0-1815.98216.000
h9shaft0-4315.95716.000
k6shaft+12+116.00116.012
m6shaft+18+716.00716.018
n6shaft+23+1216.01216.023
p6shaft+29+1816.01816.029
r6shaft+34+2316.02316.034
F8hole+43+1616.01616.043
G7hole+24+616.00616.024
H11hole+110016.00016.110
H6hole+11016.00016.011
H7hole+18016.00016.018
H8hole+27016.00016.027
H9hole+43016.00016.043
K7hole+6-1215.98816.006
N7hole-5-2315.97715.995
P7hole-11-2915.97115.989

Links go to that designation's page for this size where one exists, and to its full size table otherwise.

Standard Fits Available at 16 mm

What each standard hole/shaft pair gives at 16 mm, loosest first. Negative clearance is interference.

ISO 286 fits and their clearance at 16 mm nominal size
PropertyPropertyClearance, µmProperty
FitTypeMinMaxWhat it is for
H7/h6clearance0+29Locational clearance. Assembles by hand, no free movement intended.
H11/c11clearance+95+315Loose running. Wide commercial tolerances, large clearance for dirt, paint and thermal growth.
H9/d9clearance+50+136Free running. Good where accuracy is not essential and clearance can be generous.
H8/e8clearance+32+86Running fit with room for a lubricant film at speed.
H8/f7clearance+16+61Close running. The general-purpose lubricated journal fit.
H7/g6clearance+6+35Sliding. Locates accurately, still moves and turns freely.
H7/k6transition-12+17Locational transition. Accurate location, assembles with light force.
H7/m6transition-18+11Locational transition, tighter than k6.
H7/n6transition-23+6Tight transition. Usually a press job.
H7/p6interference-290Locational interference. Rigid location in steel without the load capacity of a drive fit.
H7/r6interference-34-5Medium drive. The joint itself carries load.
F8/h7clearance+16+61Close running, shaft basis.
G7/h6clearance+6+35Sliding, shaft basis. The h6 shaft is the reference and the hole carries the clearance.
K7/h6transition-12+17Locational transition, shaft basis.
N7/h6transition-23+6Tight transition, shaft basis.
P7/h6interference-290Locational interference, shaft basis.

Minimum clearance is the largest shaft in the smallest hole; maximum clearance is the smallest shaft in the largest hole.

Sources and Method for the 16 mm p6 Tolerance

16 mm p6 limitscomputed

limits computed from the compiled ISO 286 tables: ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed

Computed from the standard's formulas, then checked against published tables.

IT tolerance gradescompiled

ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed. Formula per ISO 286-1 standard tolerance factor and fundamental deviation formulas, used as a validation harness only per docs/research/data-sourcing.md §3.6

Compiled from independent public sources that agree cell-for-cell.

Formula

Limits from the deviations at 16 mm

max Ø  =  16 mm + (+29 µm)  =  16.029 mm
min Ø  =  16 mm + (+18 µm)  =  16.018 mm

The deviations are compiled from the ISO 286-2 tables; the limits are those deviations applied to the nominal size.

Assumptions
  • Values apply at the ISO 286 reference temperature of 20 °C.
  • Size only. Form, roundness, cylindricity and surface finish are separate callouts and a part inside these limits can still be unusable without them.
  • Dataset scope: COMPILED not computed: the ISO 286-1 formula deviates up to 13.26% from the table and is used only as a harness (warn >5%, fail >15%). EXCLUDED: shaft/hole letters s, t, u and the fits H7/s6, H7/t6, H7/u6 — no free source and an undetermined step constant in the formula.
Data last verified
August 1, 2026
How this data is built and checked →

How to Cite This 16 mm p6 Tolerance Reference

Citation

ShopMath. "16 mm p6 Tolerance — Shaft Limits in mm and µm." ShopMath, verified August 1, 2026, https://shopmath.org/fits/p6/16mm

BibTeX

@misc{shopmath-fits-p6-16mm,
  title        = {16 mm p6 Tolerance — Shaft Limits in mm and µm},
  author       = {{ShopMath}},
  year         = {2026},
  howpublished = {\url{https://shopmath.org/fits/p6/16mm}},
  note         = {Data verified 2026-08-01}
}

Permanent URL

https://shopmath.org/fits/p6/16mm

Common Questions About the 16 mm p6 Tolerance

What is the tolerance for a 16 mm p6 shaft?

A 16 mm p6 shaft runs 16.018 to 16.029 mm — deviations of +18 to +29 µm, a band 11 µm wide.

What is the maximum and minimum size of a 16 mm p6 shaft?

Maximum 16.029 mm, minimum 16.018 mm. Anything outside that band is a reject at 20 °C, not a judgement call.

Why is the IT6 band 11 µm at 16 mm?

Because 16 mm falls in the ISO 286 size band over 10 up to 18 mm, and IT6 is defined per band rather than per size. Every nominal size in that band carries the same 11 µm width for IT6.

What shaft goes in a 16 mm p6 hole?

At 16 mm the standard pairs run from H7/h6 (0 to +29 µm clearance) through transition to interference fits — the full list with clearances is on this page.

What does the p in p6 mean?

Light interference. It fixes the fundamental deviation — the limit nearest the nominal size — while IT6 fixes the width of the band, which at 16 mm is 11 µm.

All 13 p6 sizes · ISO 286 tolerance chart · Every designation and fit