Skip to content

ISO 286 · H7 hole · Ø10 mm

10 mm H7 Tolerance — Hole Limits in mm and µm

A 10 mm H7 hole is 10.000 to 10.015 mm — deviations of 0 to +15 µm on an IT7 band 15 µm wide. The default basic hole in hole-basis fitting — reamer and gauge sizes are built around it. Values apply at the ISO 286 reference temperature of 20 °C.

Nominal
10 mm
Designation
H7
Feature
hole
Grade
IT7
Band
15 µm

10 mm H7 hole · limits, mm

10.000 … 10.015

Upper dev
+15µm
Lower dev
0µm
Band
15µm

Measured at 20 °C on a plain cylindrical feature. The IT7 grade sets the 15 µm width; the H sets where the band sits.

Limits for a 10 mm H7 Hole

Deviations in micrometres, finished limits in millimetres. Both describe the same band — the deviation is what a drawing carries, the limit is what a gauge reads.

10 mm H7 hole tolerance — deviations and limits
Limitµmmm
Upper deviation+150.015
Lower deviation00.000
Maximum diameter+1510.015
Minimum diameter010.000
Tolerance band (IT7)150.015

Deviations are relative to the 10 mm nominal size. Values apply at the ISO 286 reference temperature of 20 °C; a part measured warm is not at these limits.

ISO 286 Tolerance Grades at 10 mm

10 mm falls in the ISO 286 size band over 6 to 10 mm, so every tolerance in that band has the same width regardless of which letter it carries.

ISO 286 standard tolerance grades at 10 mm nominal size
GradeTolerance, µmTolerance, mm
IT560.006
IT690.009
IT7150.015
IT8220.022
IT9360.036
IT10580.058
IT11900.090
IT121500.150

The grade sets the width of the band; the letter sets where that band sits relative to the nominal size.

Every Other ISO 286 Tolerance at 10 mm

The same nominal size under every other designation in this reference — the comparison that decides whether a feature is called out H7 or something looser.

ISO 286 hole and shaft tolerances at 10 mm nominal size
PropertyPropertyDeviation, µmLimits, mm
DesignationApplies toUpperLowerMinMax
c11shaft-80-1709.8309.920
d9shaft-40-769.9249.960
e8shaft-25-479.9539.975
f7shaft-13-289.9729.987
g6shaft-5-149.9869.995
h11shaft0-909.91010.000
h6shaft0-99.99110.000
h7shaft0-159.98510.000
h9shaft0-369.96410.000
k6shaft+10+110.00110.010
m6shaft+15+610.00610.015
n6shaft+19+1010.01010.019
p6shaft+24+1510.01510.024
r6shaft+28+1910.01910.028
F8hole+35+1310.01310.035
G7hole+20+510.00510.020
H11hole+90010.00010.090
H6hole+9010.00010.009
H7hole+15010.00010.015
H8hole+22010.00010.022
H9hole+36010.00010.036
K7hole+5-109.99010.005
N7hole-4-199.9819.996
P7hole-9-249.9769.991

Links go to that designation's page for this size where one exists, and to its full size table otherwise.

Standard Fits Available at 10 mm

What each standard hole/shaft pair gives at 10 mm, loosest first. Negative clearance is interference.

ISO 286 fits and their clearance at 10 mm nominal size
PropertyPropertyClearance, µmProperty
FitTypeMinMaxWhat it is for
H7/h6clearance0+24Locational clearance. Assembles by hand, no free movement intended.
H11/c11clearance+80+260Loose running. Wide commercial tolerances, large clearance for dirt, paint and thermal growth.
H9/d9clearance+40+112Free running. Good where accuracy is not essential and clearance can be generous.
H8/e8clearance+25+69Running fit with room for a lubricant film at speed.
H8/f7clearance+13+50Close running. The general-purpose lubricated journal fit.
H7/g6clearance+5+29Sliding. Locates accurately, still moves and turns freely.
H7/k6transition-10+14Locational transition. Accurate location, assembles with light force.
H7/m6transition-15+9Locational transition, tighter than k6.
H7/n6transition-19+5Tight transition. Usually a press job.
H7/p6interference-240Locational interference. Rigid location in steel without the load capacity of a drive fit.
H7/r6interference-28-4Medium drive. The joint itself carries load.
F8/h7clearance+13+50Close running, shaft basis.
G7/h6clearance+5+29Sliding, shaft basis. The h6 shaft is the reference and the hole carries the clearance.
K7/h6transition-10+14Locational transition, shaft basis.
N7/h6transition-19+5Tight transition, shaft basis.
P7/h6interference-240Locational interference, shaft basis.

Minimum clearance is the largest shaft in the smallest hole; maximum clearance is the smallest shaft in the largest hole.

Sources and Method for the 10 mm H7 Tolerance

10 mm H7 limitscomputed

limits computed from the compiled ISO 286 tables: ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed

Computed from the standard's formulas, then checked against published tables.

IT tolerance gradescompiled

ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed. Formula per ISO 286-1 standard tolerance factor and fundamental deviation formulas, used as a validation harness only per docs/research/data-sourcing.md §3.6

Compiled from independent public sources that agree cell-for-cell.

Formula

Limits from the deviations at 10 mm

max Ø  =  10 mm + (+15 µm)  =  10.015 mm
min Ø  =  10 mm + (0 µm)  =  10.000 mm

The deviations are compiled from the ISO 286-2 tables; the limits are those deviations applied to the nominal size.

Assumptions
  • Values apply at the ISO 286 reference temperature of 20 °C.
  • Size only. Form, roundness, cylindricity and surface finish are separate callouts and a part inside these limits can still be unusable without them.
  • Dataset scope: COMPILED not computed: the ISO 286-1 formula deviates up to 13.26% from the table and is used only as a harness (warn >5%, fail >15%). EXCLUDED: shaft/hole letters s, t, u and the fits H7/s6, H7/t6, H7/u6 — no free source and an undetermined step constant in the formula.
Data last verified
August 1, 2026
How this data is built and checked →

How to Cite This 10 mm H7 Tolerance Reference

Citation

ShopMath. "10 mm H7 Tolerance — Hole Limits in mm and µm." ShopMath, verified August 1, 2026, https://shopmath.org/fits/h7/10mm

BibTeX

@misc{shopmath-fits-h7-10mm,
  title        = {10 mm H7 Tolerance — Hole Limits in mm and µm},
  author       = {{ShopMath}},
  year         = {2026},
  howpublished = {\url{https://shopmath.org/fits/h7/10mm}},
  note         = {Data verified 2026-08-01}
}

Permanent URL

https://shopmath.org/fits/h7/10mm

Common Questions About the 10 mm H7 Tolerance

What is the tolerance for a 10 mm H7 hole?

A 10 mm H7 hole runs 10.000 to 10.015 mm — deviations of 0 to +15 µm, a band 15 µm wide.

What is the maximum and minimum size of a 10 mm H7 hole?

Maximum 10.015 mm, minimum 10.000 mm. Anything outside that band is a reject at 20 °C, not a judgement call.

Why is the IT7 band 15 µm at 10 mm?

Because 10 mm falls in the ISO 286 size band over 6 up to 10 mm, and IT7 is defined per band rather than per size. Every nominal size in that band carries the same 15 µm width for IT7.

What shaft goes in a 10 mm H7 hole?

At 10 mm the standard pairs run from H7/h6 (0 to +24 µm clearance) through transition to interference fits — the full list with clearances is on this page.

What does the H in H7 mean?

Zero deviation — the basic hole. It fixes the fundamental deviation — the limit nearest the nominal size — while IT7 fixes the width of the band, which at 10 mm is 15 µm.

All 13 H7 sizes · ISO 286 tolerance chart · Every designation and fit