Skip to content

ISO 286 · p6 shaft · Ø100 mm

100 mm p6 Tolerance — Shaft Limits in mm and µm

A 100 mm p6 shaft is 100.037 to 100.059 mm — deviations of +37 to +59 µm on an IT6 band 22 µm wide. Light interference shaft for locational press fits in steel. Values apply at the ISO 286 reference temperature of 20 °C.

Nominal
100 mm
Designation
p6
Feature
shaft
Grade
IT6
Band
22 µm

100 mm p6 shaft · limits, mm

100.037 … 100.059

Upper dev
+59µm
Lower dev
+37µm
Band
22µm

Measured at 20 °C on a plain cylindrical feature. The IT6 grade sets the 22 µm width; the p sets where the band sits.

Limits for a 100 mm p6 Shaft

Deviations in micrometres, finished limits in millimetres. Both describe the same band — the deviation is what a drawing carries, the limit is what a gauge reads.

100 mm p6 shaft tolerance — deviations and limits
Limitµmmm
Upper deviation+590.059
Lower deviation+370.037
Maximum diameter+59100.059
Minimum diameter+37100.037
Tolerance band (IT6)220.022

Deviations are relative to the 100 mm nominal size. Values apply at the ISO 286 reference temperature of 20 °C; a part measured warm is not at these limits.

ISO 286 Tolerance Grades at 100 mm

100 mm falls in the ISO 286 size band over 80 to 120 mm, so every tolerance in that band has the same width regardless of which letter it carries.

ISO 286 standard tolerance grades at 100 mm nominal size
GradeTolerance, µmTolerance, mm
IT5150.015
IT6220.022
IT7350.035
IT8540.054
IT9870.087
IT101400.140
IT112200.220
IT123500.350

The grade sets the width of the band; the letter sets where that band sits relative to the nominal size.

Every Other ISO 286 Tolerance at 100 mm

The same nominal size under every other designation in this reference — the comparison that decides whether a feature is called out p6 or something looser.

ISO 286 hole and shaft tolerances at 100 mm nominal size
PropertyPropertyDeviation, µmLimits, mm
DesignationApplies toUpperLowerMinMax
c11shaft-170-39099.61099.830
d9shaft-120-20799.79399.880
e8shaft-72-12699.87499.928
f7shaft-36-7199.92999.964
g6shaft-12-3499.96699.988
h11shaft0-22099.780100.000
h6shaft0-2299.978100.000
h7shaft0-3599.965100.000
h9shaft0-8799.913100.000
k6shaft+25+3100.003100.025
m6shaft+35+13100.013100.035
n6shaft+45+23100.023100.045
p6shaft+59+37100.037100.059
r6shaft+73+51100.051100.073
F8hole+90+36100.036100.090
G7hole+47+12100.012100.047
H11hole+2200100.000100.220
H6hole+220100.000100.022
H7hole+350100.000100.035
H8hole+540100.000100.054
H9hole+870100.000100.087
K7hole+10-2599.975100.010
N7hole-10-4599.95599.990
P7hole-24-5999.94199.976

Links go to that designation's page for this size where one exists, and to its full size table otherwise.

Standard Fits Available at 100 mm

What each standard hole/shaft pair gives at 100 mm, loosest first. Negative clearance is interference.

ISO 286 fits and their clearance at 100 mm nominal size
PropertyPropertyClearance, µmProperty
FitTypeMinMaxWhat it is for
H7/h6clearance0+57Locational clearance. Assembles by hand, no free movement intended.
H11/c11clearance+170+610Loose running. Wide commercial tolerances, large clearance for dirt, paint and thermal growth.
H9/d9clearance+120+294Free running. Good where accuracy is not essential and clearance can be generous.
H8/e8clearance+72+180Running fit with room for a lubricant film at speed.
H8/f7clearance+36+125Close running. The general-purpose lubricated journal fit.
H7/g6clearance+12+69Sliding. Locates accurately, still moves and turns freely.
H7/k6transition-25+32Locational transition. Accurate location, assembles with light force.
H7/m6transition-35+22Locational transition, tighter than k6.
H7/n6transition-45+12Tight transition. Usually a press job.
H7/p6interference-59-2Locational interference. Rigid location in steel without the load capacity of a drive fit.
H7/r6interference-73-16Medium drive. The joint itself carries load.
F8/h7clearance+36+125Close running, shaft basis.
G7/h6clearance+12+69Sliding, shaft basis. The h6 shaft is the reference and the hole carries the clearance.
K7/h6transition-25+32Locational transition, shaft basis.
N7/h6transition-45+12Tight transition, shaft basis.
P7/h6interference-59-2Locational interference, shaft basis.

Minimum clearance is the largest shaft in the smallest hole; maximum clearance is the smallest shaft in the largest hole.

Sources and Method for the 100 mm p6 Tolerance

100 mm p6 limitscomputed

limits computed from the compiled ISO 286 tables: ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed

Computed from the standard's formulas, then checked against published tables.

IT tolerance gradescompiled

ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed. Formula per ISO 286-1 standard tolerance factor and fundamental deviation formulas, used as a validation harness only per docs/research/data-sourcing.md §3.6

Compiled from independent public sources that agree cell-for-cell.

Formula

Limits from the deviations at 100 mm

max Ø  =  100 mm + (+59 µm)  =  100.059 mm
min Ø  =  100 mm + (+37 µm)  =  100.037 mm

The deviations are compiled from the ISO 286-2 tables; the limits are those deviations applied to the nominal size.

Assumptions
  • Values apply at the ISO 286 reference temperature of 20 °C.
  • Size only. Form, roundness, cylindricity and surface finish are separate callouts and a part inside these limits can still be unusable without them.
  • Dataset scope: COMPILED not computed: the ISO 286-1 formula deviates up to 13.26% from the table and is used only as a harness (warn >5%, fail >15%). EXCLUDED: shaft/hole letters s, t, u and the fits H7/s6, H7/t6, H7/u6 — no free source and an undetermined step constant in the formula.
Data last verified
August 1, 2026
How this data is built and checked →

How to Cite This 100 mm p6 Tolerance Reference

Citation

ShopMath. "100 mm p6 Tolerance — Shaft Limits in mm and µm." ShopMath, verified August 1, 2026, https://shopmath.org/fits/p6/100mm

BibTeX

@misc{shopmath-fits-p6-100mm,
  title        = {100 mm p6 Tolerance — Shaft Limits in mm and µm},
  author       = {{ShopMath}},
  year         = {2026},
  howpublished = {\url{https://shopmath.org/fits/p6/100mm}},
  note         = {Data verified 2026-08-01}
}

Permanent URL

https://shopmath.org/fits/p6/100mm

Common Questions About the 100 mm p6 Tolerance

What is the tolerance for a 100 mm p6 shaft?

A 100 mm p6 shaft runs 100.037 to 100.059 mm — deviations of +37 to +59 µm, a band 22 µm wide.

What is the maximum and minimum size of a 100 mm p6 shaft?

Maximum 100.059 mm, minimum 100.037 mm. Anything outside that band is a reject at 20 °C, not a judgement call.

Why is the IT6 band 22 µm at 100 mm?

Because 100 mm falls in the ISO 286 size band over 80 up to 120 mm, and IT6 is defined per band rather than per size. Every nominal size in that band carries the same 22 µm width for IT6.

What shaft goes in a 100 mm p6 hole?

At 100 mm the standard pairs run from H7/h6 (0 to +57 µm clearance) through transition to interference fits — the full list with clearances is on this page.

What does the p in p6 mean?

Light interference. It fixes the fundamental deviation — the limit nearest the nominal size — while IT6 fixes the width of the band, which at 100 mm is 22 µm.

All 13 p6 sizes · ISO 286 tolerance chart · Every designation and fit