Skip to content

ISO 286 · p6 shaft · Ø80 mm

80 mm p6 Tolerance — Shaft Limits in mm and µm

A 80 mm p6 shaft is 80.032 to 80.051 mm — deviations of +32 to +51 µm on an IT6 band 19 µm wide. Light interference shaft for locational press fits in steel. Values apply at the ISO 286 reference temperature of 20 °C.

Nominal
80 mm
Designation
p6
Feature
shaft
Grade
IT6
Band
19 µm

80 mm p6 shaft · limits, mm

80.032 … 80.051

Upper dev
+51µm
Lower dev
+32µm
Band
19µm

Measured at 20 °C on a plain cylindrical feature. The IT6 grade sets the 19 µm width; the p sets where the band sits.

Limits for a 80 mm p6 Shaft

Deviations in micrometres, finished limits in millimetres. Both describe the same band — the deviation is what a drawing carries, the limit is what a gauge reads.

80 mm p6 shaft tolerance — deviations and limits
Limitµmmm
Upper deviation+510.051
Lower deviation+320.032
Maximum diameter+5180.051
Minimum diameter+3280.032
Tolerance band (IT6)190.019

Deviations are relative to the 80 mm nominal size. Values apply at the ISO 286 reference temperature of 20 °C; a part measured warm is not at these limits.

ISO 286 Tolerance Grades at 80 mm

80 mm falls in the ISO 286 size band over 50 to 80 mm, so every tolerance in that band has the same width regardless of which letter it carries.

ISO 286 standard tolerance grades at 80 mm nominal size
GradeTolerance, µmTolerance, mm
IT5130.013
IT6190.019
IT7300.030
IT8460.046
IT9740.074
IT101200.120
IT111900.190
IT123000.300

The grade sets the width of the band; the letter sets where that band sits relative to the nominal size.

Every Other ISO 286 Tolerance at 80 mm

The same nominal size under every other designation in this reference — the comparison that decides whether a feature is called out p6 or something looser.

ISO 286 hole and shaft tolerances at 80 mm nominal size
PropertyPropertyDeviation, µmLimits, mm
DesignationApplies toUpperLowerMinMax
c11shaft-150-34079.66079.850
d9shaft-100-17479.82679.900
e8shaft-60-10679.89479.940
f7shaft-30-6079.94079.970
g6shaft-10-2979.97179.990
h11shaft0-19079.81080.000
h6shaft0-1979.98180.000
h7shaft0-3079.97080.000
h9shaft0-7479.92680.000
k6shaft+21+280.00280.021
m6shaft+30+1180.01180.030
n6shaft+39+2080.02080.039
p6shaft+51+3280.03280.051
r6shaft+62+4380.04380.062
F8hole+76+3080.03080.076
G7hole+40+1080.01080.040
H11hole+190080.00080.190
H6hole+19080.00080.019
H7hole+30080.00080.030
H8hole+46080.00080.046
H9hole+74080.00080.074
K7hole+9-2179.97980.009
N7hole-9-3979.96179.991
P7hole-21-5179.94979.979

Links go to that designation's page for this size where one exists, and to its full size table otherwise.

Standard Fits Available at 80 mm

What each standard hole/shaft pair gives at 80 mm, loosest first. Negative clearance is interference.

ISO 286 fits and their clearance at 80 mm nominal size
PropertyPropertyClearance, µmProperty
FitTypeMinMaxWhat it is for
H7/h6clearance0+49Locational clearance. Assembles by hand, no free movement intended.
H11/c11clearance+150+530Loose running. Wide commercial tolerances, large clearance for dirt, paint and thermal growth.
H9/d9clearance+100+248Free running. Good where accuracy is not essential and clearance can be generous.
H8/e8clearance+60+152Running fit with room for a lubricant film at speed.
H8/f7clearance+30+106Close running. The general-purpose lubricated journal fit.
H7/g6clearance+10+59Sliding. Locates accurately, still moves and turns freely.
H7/k6transition-21+28Locational transition. Accurate location, assembles with light force.
H7/m6transition-30+19Locational transition, tighter than k6.
H7/n6transition-39+10Tight transition. Usually a press job.
H7/p6interference-51-2Locational interference. Rigid location in steel without the load capacity of a drive fit.
H7/r6interference-62-13Medium drive. The joint itself carries load.
F8/h7clearance+30+106Close running, shaft basis.
G7/h6clearance+10+59Sliding, shaft basis. The h6 shaft is the reference and the hole carries the clearance.
K7/h6transition-21+28Locational transition, shaft basis.
N7/h6transition-39+10Tight transition, shaft basis.
P7/h6interference-51-2Locational interference, shaft basis.

Minimum clearance is the largest shaft in the smallest hole; maximum clearance is the smallest shaft in the largest hole.

Sources and Method for the 80 mm p6 Tolerance

80 mm p6 limitscomputed

limits computed from the compiled ISO 286 tables: ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed

Computed from the standard's formulas, then checked against published tables.

IT tolerance gradescompiled

ISO 286-1 IT grades and ISO 286-2 fundamental deviations, compiled from saucecode/ISO286 (LGPL-2.1) and parkergreene/isofits (MIT), cross-checked cell-for-cell

Verified against parkergreene/isofits ISO 286-2 limit tables (MIT); ISO 286-1 formula harness — 2067 checks passed. Formula per ISO 286-1 standard tolerance factor and fundamental deviation formulas, used as a validation harness only per docs/research/data-sourcing.md §3.6

Compiled from independent public sources that agree cell-for-cell.

Formula

Limits from the deviations at 80 mm

max Ø  =  80 mm + (+51 µm)  =  80.051 mm
min Ø  =  80 mm + (+32 µm)  =  80.032 mm

The deviations are compiled from the ISO 286-2 tables; the limits are those deviations applied to the nominal size.

Assumptions
  • Values apply at the ISO 286 reference temperature of 20 °C.
  • Size only. Form, roundness, cylindricity and surface finish are separate callouts and a part inside these limits can still be unusable without them.
  • Dataset scope: COMPILED not computed: the ISO 286-1 formula deviates up to 13.26% from the table and is used only as a harness (warn >5%, fail >15%). EXCLUDED: shaft/hole letters s, t, u and the fits H7/s6, H7/t6, H7/u6 — no free source and an undetermined step constant in the formula.
Data last verified
August 1, 2026
How this data is built and checked →

How to Cite This 80 mm p6 Tolerance Reference

Citation

ShopMath. "80 mm p6 Tolerance — Shaft Limits in mm and µm." ShopMath, verified August 1, 2026, https://shopmath.org/fits/p6/80mm

BibTeX

@misc{shopmath-fits-p6-80mm,
  title        = {80 mm p6 Tolerance — Shaft Limits in mm and µm},
  author       = {{ShopMath}},
  year         = {2026},
  howpublished = {\url{https://shopmath.org/fits/p6/80mm}},
  note         = {Data verified 2026-08-01}
}

Permanent URL

https://shopmath.org/fits/p6/80mm

Common Questions About the 80 mm p6 Tolerance

What is the tolerance for a 80 mm p6 shaft?

A 80 mm p6 shaft runs 80.032 to 80.051 mm — deviations of +32 to +51 µm, a band 19 µm wide.

What is the maximum and minimum size of a 80 mm p6 shaft?

Maximum 80.051 mm, minimum 80.032 mm. Anything outside that band is a reject at 20 °C, not a judgement call.

Why is the IT6 band 19 µm at 80 mm?

Because 80 mm falls in the ISO 286 size band over 50 up to 80 mm, and IT6 is defined per band rather than per size. Every nominal size in that band carries the same 19 µm width for IT6.

What shaft goes in a 80 mm p6 hole?

At 80 mm the standard pairs run from H7/h6 (0 to +49 µm clearance) through transition to interference fits — the full list with clearances is on this page.

What does the p in p6 mean?

Light interference. It fixes the fundamental deviation — the limit nearest the nominal size — while IT6 fixes the width of the band, which at 80 mm is 19 µm.

All 13 p6 sizes · ISO 286 tolerance chart · Every designation and fit